Phosphor thermometry is a non-contact technology that holds promise for measuring temperatures of gas turbine. This paper investigated the effects of angle and distance on phosphor thermometry of four distinct samples. The results revealed that different samples responded differently to angles and distances. For YSZ: Dy and YSZ: Sm powders, the maximum effect on the thermometry results were observed 3% and 12.8%, respectively.
| Original language | English |
|---|---|
| Journal | ICAS Proceedings |
| State | Published - 2024 |
| Event | 34th Congress of the International Council of the Aeronautical Sciences, ICAS 2024 - Florence, Italy Duration: 9 Sep 2024 → 13 Sep 2024 |
Keywords
- Aeroengine
- Angle and distance effect
- Phosphor thermometry
Fingerprint