Abstract
Vibration error of fiber optic gyro affects its application performance directly. In order to solve the problem, the main causes of vibration error were analyzed. The expression between the closed-loop gyro output and optical power was conducted. The conclusion is that the inner stress of the fiber coil and the device pigtail caused by vibration leads to the variation of the polarization mode and optical power of propagating light. The vibration status of gyro mechanical structure, especially the resonance feature, was analyzed with the method of finite element analysis (FEA) and verified by tests. So from the view of design and technique, some effective measures to improve the dynamic performance were put forward, including disposal of fiber coil and optical device pigtail, resonance free with reasonable structure design and improvement of closed-loop control. The result shows that the methods are valid. In vibration condition, the dynamic precision of fiber optic gyro is near static performance and satisfies application need.
| Original language | English |
|---|---|
| Pages (from-to) | 702-704 |
| Number of pages | 3 |
| Journal | Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics |
| Volume | 30 |
| Issue number | 8 |
| State | Published - Aug 2004 |
Keywords
- Closed-loop control
- Error
- Fiber optics
- Finite element analysis
- Gyroscope
- Vibration