Skip to main navigation Skip to search Skip to main content

Analysis and suppression of the input second harmonic current in two-stage inverter

  • Ren Lei
  • , Yao Zhao
  • , Chunying Gong
  • , Xiang Deng
  • , Zheng Wei
  • Nanjing University of Aeronautics and Astronautics

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

The instantaneous output power of a two-stage single-phase inverter pulsates at twice the output voltage frequency, generating second harmonic current (SHC) in the front-end dc-dc converter. Though reducing the SHC of the output filter inductor of the dc-dc converter (FIDC) can reduce the input SHC effectively, it depends on the capacitance of DC bus capacitor totally. In order to reduce the SHC of the input port more effectively, a control strategy is proposed in this paper, which extracts the SHC of the input port into the inductor current feedback path by a multiplier and a band-pass filter. The proposed control scheme can not only reduce the SHC significantly, but also is beneficial to improving the dynamic performance of the front-end dc-dc converter. Finally, a 1500-VA prototype is built, and the simulation results are presented to verify the effectiveness of the proposed control strategy.

Original languageEnglish
Title of host publicationIECON Proceedings (Industrial Electronics Conference)
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages4192-4197
Number of pages6
ISBN (Electronic)9781479940325
DOIs
StatePublished - 24 Feb 2014
Externally publishedYes

Publication series

NameIECON Proceedings (Industrial Electronics Conference)

Fingerprint

Dive into the research topics of 'Analysis and suppression of the input second harmonic current in two-stage inverter'. Together they form a unique fingerprint.