@inproceedings{280a08fcff684be28520cc541b582db1,
title = "Analysis and experimental study on continuous leakage of oxygen cylinder",
abstract = "The oxygen system is an important part of the aircraft life support system. Several continuous leakage faults occurred in a certain type of onboard oxygen system during the ground tests. In this paper, the cause of the faults was investigated and analyzed according to experiment results, and faulty components were identified. The fault phenomenon was repeated through experiments. Corresponding improvement suggestions were put forward on the basis of analysis.",
keywords = "Component: Fault analysis, Experimental study, Onboard oxygen system, Pressure reducer, Safety valve",
author = "Yu Zeng and Chenxin Guo and Zhonghua Liu and Chunmu Li and Rui Pan",
note = "Publisher Copyright: {\textcopyright} 2020 IEEE.; 5th International Conference on Mechanical, Control and Computer Engineering, ICMCCE 2020 ; Conference date: 25-12-2020 Through 27-12-2020",
year = "2020",
month = dec,
doi = "10.1109/ICMCCE51767.2020.00032",
language = "英语",
series = "Proceedings - 2020 5th International Conference on Mechanical, Control and Computer Engineering, ICMCCE 2020",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
pages = "112--116",
booktitle = "Proceedings - 2020 5th International Conference on Mechanical, Control and Computer Engineering, ICMCCE 2020",
address = "美国",
}