Abstract
Three-axis atomic magnetometers have an excellent advantage for determining the complete vector information of a magnetic field to be measured. However, the crosstalk effect, which leads to an error output on one axis owing to a magnetic field on the other axes, can reduce the measurement accuracy. In this study, we propose an effective suppression method for the crosstalk effect in a three-axis atomic magnetometer. First, we investigated and analyzed the main factors that introduce the effect. Based on this, the modulation parameters were optimized to improve the scale factors, which obtained a coupling coefficient of less than 6% for the atomic magnetometer. Subsequently, the associated transfer matrix was corrected to further suppress the crosstalk effect. After correction, all the coupling coefficients were decreased to less than 3%, with the majority being lower than 1%.
| Original language | English |
|---|---|
| Article number | 654 |
| Journal | Photonics |
| Volume | 9 |
| Issue number | 9 |
| DOIs | |
| State | Published - Sep 2022 |
Keywords
- crosstalk effect
- density matrix equation
- magnetic fields measurement
- three-axis magnetometer
Fingerprint
Dive into the research topics of 'Analysis and Correction of the Crosstalk Effect in a Three-Axis SERF Atomic Magnetometer'. Together they form a unique fingerprint.Cite this