Skip to main navigation Skip to search Skip to main content

An integral imaging three dimensional display method based on aperture stop array

  • Yao Liu
  • , Huan Deng*
  • , Chenggao Luo
  • , Qionghua Wang
  • *Corresponding author for this work
  • Sichuan University

Research output: Contribution to journalArticlepeer-review

Abstract

The performance of integral imaging three-dimensional (3D) display is limited by the limited depth-of-field. A method for enhancing the depth-of-field of integral imaging is proposed. This method adds an aperture stop array in the conventional integral imaging system, and the aperture stop array is used to limit the divergence angle of each pixel in the display panel. The principle of integral imaging is analyzed and the relationship between the size of aperture stop and the depth-of-field is studied in detail. Both the proposed method and conventional method are simulated by optical design software ASAP, and the simulation results show that the depth-of-field of the proposed method is 1.5 times of the conventional method when the aperture stop diameter accounts for 64% of the pitch micro-less. The experimental results verify the correctness of the theoretical analysis.

Original languageEnglish
Article number0910004
JournalGuangxue Xuebao/Acta Optica Sinica
Volume34
Issue number9
DOIs
StatePublished - 10 Sep 2014
Externally publishedYes

Keywords

  • Aperture stop array
  • Depth-of-field
  • Imaging systems
  • Micro-lens array
  • Three-dimensional display

Fingerprint

Dive into the research topics of 'An integral imaging three dimensional display method based on aperture stop array'. Together they form a unique fingerprint.

Cite this