Skip to main navigation Skip to search Skip to main content

A zero-field atomic gradiometer with elliptically polarized laser-pumped used for biomagnetic measurement

  • Kaifeng Yin
  • , Jing Wang
  • , Zhi Liu
  • , Yeguang Yan
  • , Huining Shang
  • , Binquan Zhou*
  • *Corresponding author for this work
  • Beihang University

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

A new design of compact zero-field atomic gradiometer was proposed and integrated using alkali vapor cell and customized optical components. This gradiometer used two parallel elliptically polarized lights, whose output intensity was measured to perform gradient magnetic field detection, respectively. To improve the gradiometer's sensitivity of the magnetic field detection, the gradiometer was operated in the spin-exchange relaxation-free (SERF) regime. For the sensitivity study, the gradiometer was placed in a person-sized four-layer μ-metal magnetic shielding. With the magnetic shield closed up, the sensitivity of each channel was near 34 fT/ √ Hz, and the corresponding gradient sensitivity could reach 14 fT/√ Hz/cm on a 1cm baseline. When the cover of magnetic shielding was removed, the magnetometer sensitivity of single channel was about 90 fT/√ Hz, and the corresponding gradient sensitivity could reach 34 fT/√ Hz/cm. The experimental results implied that in a poor magnetic shielding environment, the performance of magnetometer was limited due to the fluctuations of the environmental magnetic field, while the gradiometer could work well.

Original languageEnglish
Title of host publicationAOPC 2020
Subtitle of host publicationOptoelectronics and Nanophotonics; and Quantum Information Technology
EditorsJianyu Wang, Zhiping Zhou, Chaoyang Lu, Lixing You, Changjun Min, Haiqing Song, Guixin Li
PublisherSPIE
ISBN (Electronic)9781510639492
DOIs
StatePublished - 2020
Event2020 Applied Optics and Photonics China: Optoelectronics and Nanophotonics; and Quantum Information Technology, AOPC 2020 - Beijing, China
Duration: 30 Nov 2020 → …

Publication series

NameProceedings of SPIE - The International Society for Optical Engineering
Volume11564
ISSN (Print)0277-786X
ISSN (Electronic)1996-756X

Conference

Conference2020 Applied Optics and Photonics China: Optoelectronics and Nanophotonics; and Quantum Information Technology, AOPC 2020
Country/TerritoryChina
CityBeijing
Period30/11/20 → …

Keywords

  • atomic gradiometer
  • biomagnetic measurement
  • spin-exchange-relaxation-free magnetometer

Fingerprint

Dive into the research topics of 'A zero-field atomic gradiometer with elliptically polarized laser-pumped used for biomagnetic measurement'. Together they form a unique fingerprint.

Cite this