Abstract
This paper shows a new way for measuring temperature in interferometric fiber-optic gyroscopes based on the temperature dependence of the integrated optical circuit. No component irrelevant to rotation sensing is involved. Calibration and temperature tests were conducted. The demonstrated repeatability and resolution are better than 0.5 °C. The hysteresis error is less than 1.76% full scale. The proposed method is reliable, radiation-resistant, and simple to be implemented, which would make it suitable for space application.
| Original language | English |
|---|---|
| Article number | 7433931 |
| Pages (from-to) | 4192-4197 |
| Number of pages | 6 |
| Journal | IEEE Sensors Journal |
| Volume | 16 |
| Issue number | 11 |
| DOIs | |
| State | Published - 1 Jun 2016 |
Keywords
- Integrated Optical Circuit
- Interferometric Fiber Optic Gyroscopes
- Temperature Measurement
Fingerprint
Dive into the research topics of 'A Reliable and Efficient Method for Temperature Sensing in Interferometric Fiber-Optic Gyro'. Together they form a unique fingerprint.Cite this