Abstract

In order to avoid the oscillation of duty ratio perturbation method and make full use of solar arrays power, after establishing a model of the solar array, analyzing its input and output characteristics, and discussing the concept and principles of peak power tracking (PPT), we use fuzzy controller to modify three parameters of PID controller to modify the step of duty ratio to track the maximum power point of solar array. The simulation results show that the method can quickly and accurately track the MPP, decreases the oscillation and improve the efficiency of energy conversion of solar array.

Original languageEnglish
Title of host publicationCAR 2010 - 2010 2nd International Asia Conference on Informatics in Control, Automation and Robotics
Pages298-301
Number of pages4
DOIs
StatePublished - 2010
Event2010 2nd International Asia Conference on Informatics in Control, Automation and Robotics, CAR 2010 - Wuhan, China
Duration: 6 Mar 20107 Mar 2010

Publication series

NameCAR 2010 - 2010 2nd International Asia Conference on Informatics in Control, Automation and Robotics
Volume2

Conference

Conference2010 2nd International Asia Conference on Informatics in Control, Automation and Robotics, CAR 2010
Country/TerritoryChina
CityWuhan
Period6/03/107/03/10

Keywords

  • Fuzzy control
  • MATLAB/simulink
  • PID
  • PPT
  • Solar arrays

Fingerprint