Abstract
Purpose: This paper aims to analyze a failure case of a P110 tube in a CO2 flooding well. Design/methodology/approach: The chemical composition, microstructure and mechanical properties of the failed P110 tubing steel were tested, and met the API Spec 5CT standard. The fractures were investigated by scanning electron microscopy and energy dispersive spectroscopy. Findings: Fracture was induced by stress corrosion cracking (SCC) and that the stress concentration caused by the mechanical damage played an important role in the failure. The failure case is a SCC failure affected by mechanical damage and galvanic corrosion. Originality/value: The effect of the infiltration of groundwater was studied in the failure case. The stress concentration caused by the mechanical damage played an important role in the failure.
| Original language | English |
|---|---|
| Pages (from-to) | 453-463 |
| Number of pages | 11 |
| Journal | Anti-Corrosion Methods and Materials |
| Volume | 67 |
| Issue number | 5 |
| DOIs | |
| State | Published - 30 Sep 2020 |
| Externally published | Yes |
Keywords
- 110 steel
- Downhole tubing
- Failure analysis
- Stress corrosion cracking
Fingerprint
Dive into the research topics of 'A failure case of P110 steel tubing in CO2 flooding well'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver