Skip to main navigation Skip to search Skip to main content

A failure case of P110 steel tubing in CO2 flooding well

  • Longfei Song
  • , Zhiyong Liu*
  • , Lin Lu
  • , Xiaogang Li
  • , Bao Zhuang Sun
  • , Huanlin Cheng
  • *Corresponding author for this work
  • University of Science and Technology Beijing

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: This paper aims to analyze a failure case of a P110 tube in a CO2 flooding well. Design/methodology/approach: The chemical composition, microstructure and mechanical properties of the failed P110 tubing steel were tested, and met the API Spec 5CT standard. The fractures were investigated by scanning electron microscopy and energy dispersive spectroscopy. Findings: Fracture was induced by stress corrosion cracking (SCC) and that the stress concentration caused by the mechanical damage played an important role in the failure. The failure case is a SCC failure affected by mechanical damage and galvanic corrosion. Originality/value: The effect of the infiltration of groundwater was studied in the failure case. The stress concentration caused by the mechanical damage played an important role in the failure.

Original languageEnglish
Pages (from-to)453-463
Number of pages11
JournalAnti-Corrosion Methods and Materials
Volume67
Issue number5
DOIs
StatePublished - 30 Sep 2020
Externally publishedYes

Keywords

  • 110 steel
  • Downhole tubing
  • Failure analysis
  • Stress corrosion cracking

Fingerprint

Dive into the research topics of 'A failure case of P110 steel tubing in CO2 flooding well'. Together they form a unique fingerprint.

Cite this