A device to improveA device to improveA device to improve the SNR of the measurement of the positional floating reference point

  • Tianjin University

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

Previous studies have preliminarily validated the floating reference method and shown that it has the potential to improve the accuracy of non-invasive blood glucose sensing by Near-Infrared Spectroscopy. In order to make this method practical, it is necessary to precisely verify and measure the existence and variation features of the positional floating reference point. In this talk, a device which can precisely verify and measure the positional floating reference point is built. Since the light intensity of diffuse reflectance from the tested sample is very weak, a multipath detecting fibers system was built to improve signal-to-noise ratio. In this system, the fibers encircle the light source fiber which is regarded as the reference center of detecting fibers while they are moving. In addition, the position of each fiber is accurately controlled by manual translation stage to keep all detecting fibers always in the same radius around light source fiber. This ensures that received signal is coming from the same radial distance of light source. The variation of signal-to-noise ratio along with the different radial distance was investigated based on experiments. Results show that the application of this device could improve signal-to-noise ratio, and provide a new experimental method for the further study of positional floating reference point.

Original languageEnglish
Title of host publicationDynamics and Fluctuations in Biomedical Photonics IX
DOIs
StatePublished - 2013
Externally publishedYes
EventDynamics and Fluctuations in Biomedical Photonics VIII Conference - San Francisco, CA, United States
Duration: 2 Feb 20134 Feb 2013

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume8580
ISSN (Print)1605-7422

Conference

ConferenceDynamics and Fluctuations in Biomedical Photonics VIII Conference
Country/TerritoryUnited States
CitySan Francisco, CA
Period2/02/134/02/13

Keywords

  • Diffuse reflectance
  • Multipath detecting fibers system
  • Near-Infrared Spectroscopy
  • Positional floating reference point
  • SNR