基于CSNS反角白光中子源的中子俘获反应截面测量技术研究

Translated title of the contribution: Cross section measurement of neutron capture reaction based on back-streaming white neutron source at China spallation neutron source
  • Qi Wei Zhang
  • , Guang Yuan Luan*
  • , Jie Ren
  • , Xi Chao Ruan
  • , Guo Zhu He
  • , Jie Bao
  • , Qi Sun
  • , Han Xiong Huang
  • , Zhao Hui Wang
  • , Min Hao Gu
  • , Tao Yu
  • , Li Kun Xie
  • , Yong Hao Chen
  • , Qi An
  • , Huai Yong Bai
  • , Yu Bao
  • , Ping Cao
  • , Hao Lei Chen
  • , Qi Ping Chen
  • , Yu Kai Chen
  • Zhen Chen, Zeng Qi Cui, Rui Rui Fan, Chang Qing Feng, Ke Qing Gao, Chang Cai Han, Zi Jie Han, Yong Cheng He, Yang Hong, Wei Ling Huang, Xi Ru Huang, Xiao Lu Ji, Xu Yang Ji, Wei Jiang, Hao Yu Jiang, Zhi Jie Jiang, Han Tao Jing, Ling Kang, Ming Tao Kang, Bo Li, Chao Li, Jia Wen Li, Lun Li, Qiang Li, Xiao Li, Yang Li, Rong Liu, Shu Bin Liu, Xing Yan Liu, Qi Li Mu, Chang Jun Ning, Bin Bin Qi, Zhi Zhou Ren, Ying Peng Song, Zhao Hui Song, Hong Sun, Kang Sun, Xiao Yang Sun, Zhi Jia Sun, Zhi Xin Tan, Hong Qing Tang, Jing Yu Tang, Xin Yi Tang, Bin Bin Tian, Li Jiao Wang, Peng Cheng Wang, Qi Wang, Tao Feng Wang, Jie Wen, Zhong Wei Wen, Qing Biao Wu, Xiao Guang Wu, Xuan Wu, Yi Wei Yang, Han Yi, Li Yu, Yong Ji Yu, Guo Hui Zhang, Lin Hao Zhang, Xian Peng Zhang, Yu Liang Zhang, Zhi Yong Zhang, Yu Bin Zhao, Lu Ping Zhou, Zu Ying Zhou, Dan Yang Zhu, Ke Jun Zhu, Peng Zhu, Xing Hua Zhu
*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

The data of neutron capture cross section are very important for the research of nuclear astrophysics, advanced nuclear energy development. Owing to the limitation of neutron source and detector, the experimental data of neutron capture cross section in an energy range of 1 eV-10 keV were almost blank in China. The first Chinese gamma-ray total absorption facility has been constructed in the key laboratory of nuclear data at China institute of atomic energy, which consists of 40 BaF2 detector units. The BaF2 crystal shell with a thickness of 15 cm and an inner radius of 10 cm covers 95.2% of the solid angle. On-line measurement method of neutron capture reaction cross section is established on the back-streaming white neutron source of China spallation neutron source by using the upgraded facility. The cross section of 197Au neutron capture reaction is measured for the first time under the experimental condition of irregular 30 mm neutron beam spot. The measured position of resonance peak is well consistent with the relevant data of ENDF evaluation database, which verifies the reliability of the measurement device and measurement technology, and thus laying the foundation for the acquisition of high precision cross section in future.

Translated title of the contributionCross section measurement of neutron capture reaction based on back-streaming white neutron source at China spallation neutron source
Original languageChinese (Traditional)
Article number222801
JournalWuli Xuebao/Acta Physica Sinica
Volume70
Issue number22
DOIs
StatePublished - 20 Nov 2021

Fingerprint

Dive into the research topics of 'Cross section measurement of neutron capture reaction based on back-streaming white neutron source at China spallation neutron source'. Together they form a unique fingerprint.

Cite this