Skip to main navigation Skip to search Skip to main content

基于 XPBD 的微创冠脉旁路移植手术操作实时仿真

Translated title of the contribution: XPBD-Based Real-Time Simulation Method for Minimally Invasive Coronary Artery Bypass Graft Surgery Operations
  • Xixuan Li
  • , Zhenhao Dou
  • , Hongyu Wu*
  • *Corresponding author for this work
  • Beihang University

Research output: Contribution to journalArticlepeer-review

Abstract

Minimally invasive coronary artery bypass grafting (MICS-CABG) is an important development in the surgical treatment of severe coronary artery disease, but MICS-CABG is difficult and risky, and trainees cannot directly train surgical skills in actual patients. The virtual reality-based surgical simulation training can effectively improve the training effect and avoid surgical risks. For the characteristics of MICS-CABG, we propose a real-time simulation method of minimally invasive coronary artery bypass grafting operation based on XPBD framework. A tetrahedral exoskeleton model is used to realize the physical deformation of the heart, and a cylindrical geometry is used to represent the physical model of the surgical instrument. Based on the GPU-accelerated XPBD simulation framework, we established the Cosserat constraints based on XPBD, using the coronary artery mid-axis to achieve the coronary artery deformation simulation, and used tetrahedral volume constraints to achieve the heart deformation simulation. Furthermore, based on the collision detection between the surgical instrument and the physical model of the heart, non-embedding constraints and attachment constraints were introduced to generate the feedback force for the interaction between the tool and the soft tissue. The experimental results show that the proposed method has high simulation efficiency and stability in real-time interaction between the surgical instrument model and soft tissue model. In the simulation scenario containing 100 000 physical units, the simulation rate can reach 60frames/s. with the force feedback simulation frequency over 1 kHz, which can maintain a high-quality visual effect.

Translated title of the contributionXPBD-Based Real-Time Simulation Method for Minimally Invasive Coronary Artery Bypass Graft Surgery Operations
Original languageChinese (Traditional)
Pages (from-to)1842-1851
Number of pages10
JournalJisuanji Fuzhu Sheji Yu Tuxingxue Xuebao/Journal of Computer-Aided Design and Computer Graphics
Volume36
Issue number11
DOIs
StatePublished - Nov 2024

Fingerprint

Dive into the research topics of 'XPBD-Based Real-Time Simulation Method for Minimally Invasive Coronary Artery Bypass Graft Surgery Operations'. Together they form a unique fingerprint.

Cite this